Specifications for the NM200EVT-1 Nuclear Underwater Laser Scanner

  

Item Control Unit Camera Head
Technical Specifications
System Performance
Item
Control Unit
Measurement Head
Height 14.75 in. (374.65 mm)) 4.250 in. (107,950 mm)
Width 26.75 in. (679.45 mm) 4.625 in. (117,475 mm)
Length 27.50 in. (698.5 mm) 9.375 in. (238,125 mm)
Weight (in air) 84.5 lbs. (38.3 kg) 8 lbs. (4 kg)
Weight (in water) --- 2 lbs. (1 kg) (plus cable weight)
Construction Metal electronics rack suspended on eight shock absorbers within a molded, high-impact, airline-transportable case Machined from solid billet of 6061T6 aluminum stock
Cable LLDPE polyurethane jacket, gel filled - 150 ft. (45.72 m) (other lengths available) ---
Cable weight - 150 ft. (in air) 23.6 lbs. (10.7 kg) ---
Laser power --- 40 mW
Video camera --- High resolution monochrome
LED ring array --- 2,320 lumens
Fittings & retainers --- 300 series stainless steel
Windows --- Fused silica or optical glass
Mounting attachments --- Four grouped 1/4-20 UNC threaded mounting holes on four sides of case (Metric threads available)
Output ports Ethernet, USB, DVI, VGA & HDMI ---
Operating temperature 40° to 110° F (5° to 43° C) 110° F (43.3° C ) in water - 100% duty cycle
Storage temperature 0° to 125° F (-18° to 52° C) 0° to 160° F (- 18° to 71° C)
Power input voltage/current 100 to 240 VAC 50 to 60 cycle Powered by control unit
Data storage Internal solid state & USB stick data ---
Output formats .ply point cloud file ---
Data file size Approximately 100 MB per scan ---
Maximum scanner-to-target distance --- 36.0 in. (900mm)
Minimum scanner-to-target distance --- 6.0 in. (150mm)
Maximum Resolution accuracy
(after processing with 3D software)
--- +/-0.0004 in. (0.01mm)
Scan range --- 6.0 in. to 36 in.
(150 mm to 900 mm)
Watertight depth rating --- 150 ft. (46 m)
Power/Data Umbilical Cable Gel filled gel-filled with LLDPE polyurethane jacket and a rated yield point of 80 lb/ft (11 Kg/M) - 150 ft. (45,7 m) standard (other lengths available)
     

  